Multi-Parameter Veterinary Monitor for Highly-Qualified
    Veterinarians

  • 10.4” high resolution(800X600) with maximum 10 waveforms
  • Standard Configuration : ECG, SpO2, NIBP, Resp, 2Temp, 2IBP
  • 6 Kinds of Virtual Screen
  • 3CH ECG : Full 7 ECG & ST Segment analysis
  • 12CH EKG : Full 12 EKG & ST Segment analysis

ECG(3CH) SpO2 NIBP RESP 2TEMP 2IBP HR/PR APG HRV
EKG(12CH) 4TEMP 4IBP ICO EtCO2 Touch
Screen
qCON
(BIS)
Multi
Gas
VGA
OUT
ECG/IBP
OUT
  • 10.4” high resolution(800X600) with maximum 10 waveforms
  • Standard Configuration : ECG, SpO2, NIBP, Resp, 2Temp, 2IBP
  • 6 Kinds of Virtual Screen
  • 3CH ECG : Full 7 ECG & ST Segment analysis
  • 12CH EKG : Full 12 ECG & ST Segment analysis
  • 13 Arrhythmia analysis & Pacemaker detection
  • Saves tabular and graphic trend data for 7 days
  • Multi high-end Functions
  • - Drug Dose Calculation, ECG Recall, Mini Trend, ICO, Color change, NIBP STAT

  • - NIBP VENOUS STAT, OXY-CRG, Patient information, Temp TD

  • Easy S/W upgrade with SD Card(Max 8Gbyte)
  • Durable, and light Long Li-ion battery operation
  • - Std 1Pack : 2hrs / 2Pack : 4hrs

  • LAN/Wireless LAN Connection
  • Respironics’s EtCO2 Mainstream (C5), Sidestream (LoFlo)
  • HRV, APG Detection, Touch Screen(Option)
  • Supreme Standard configuration and extendibility
  • - Standard : ECG, SpO2, NIBP, Respiration, 2Temp, 2IBP

  • - Optional : Standard + 4Temp, 4IBP, ICO, EtCO2, 12CH EKG, Touch Screen, 3CH Printer

    THE 1ST GENUINE VETERINARY MONITOR FOR VETERINARIAN IN THE WORLD

  • Developed in collaboration with Prof. Hyen's Vet. Lab at KNU for vet in the world
    The 1st Genuine Veterinary Monitor ONLY FOR Vet
    The 1st Veterinary Monitor FOR small animals (cat and dog ) that fits best for small animal clinics

    SpO2 COMPARISON TEST

  • Oxygen saturation of 10 adult dogs weighing 5 to 25kgs were measured.
    The average values were compared after measuring total 10 dogs every 10minutes for total 80 minutes.
    VOTEM’s V7
    VETSPEC’s(USA) VSM 7
    Tissue oximeter (Standard value)
    VOTEM’s V7 → ±1.5% for 80 minutes
    VETSPEC’s(USA) VSM 7 → ±5.7% for 80 minutes
    * Standard value refers to Tissue Oximeter’s measurement

    NIBP COMPARISON TEST

  • NIBP was measured from 10 adult dogs under anesthesia weighing 5 to 25kgs.
    After measuring 5 times, without using the highest and the lowest values into calculation,
    the intermediate 3 values were chosen into calculation
    VOTEM’s V7
    Doppler
    HDO
    Cardell
    IBP (Standard value)
    VOTEM’s V7 → ±7.2mmHg
    Doppler’s → ±10.2mmHg
    HDO’s → ±15.3mmHg
    Cardell → ±27.5mmHg

    SMALL SIZE BUT LARGE VIRTUAL SCREEN

  • 12.1” Monitor provides 72.6”(12.1”X6) view effect with 6 Virtual screens

    MULTI HIGH-END FUNCTIONS

  • Drug Dose Calculation ECG Recall and Analysis Mini-Trend
    Helps you to manage total quantity of drug to be delivered to the animal over time. Recalls 20 seconds event data with graphic, and 2 sec-long data can be zoomed to observe and analyze. You can see 2hrs-long mini-trend data on the main screen.
    ICO Color Change NIBP STAT
    Measures Cardiac Output (CI, SV, SI, LVSW, LVSWI, RVSW, RVSWI, SVR, SVRI, PVR, PVRI) Selectable color configuration of waveform and numeral for all parameters up to 18 colors.
    NIBP can be measured from 5 to 15 minutes automatically.
    OXY-CRG Patient Information Event Management
    Analyzes animal’s HR, SpO2, Resp., for each 0.3second during 2 minutes
    stores animal’s admission date, ID, name, gender, date of birth, weight, and height.
    Manages individual EVENT data up to 20 cases in case of Arrhythmia.

    7DAYS GRAPHIC & TABULAR TREND DATA STORAGE

  • - All parameters
    - 10,080 sets(1 set per minute) of virtual signs list data can be stored, reviewed, and printed out.

    EASY S/W UPGRADE with SD CARD (MAX. 8G Byte)

  • Able toUPGRADE S/W CONTINUOUSLY WITHOUT DISASSEMBLING THE PRODUCT WITH SD CARD.

    "3CH" THERMAL PRINTER(OPTIONAL)

    Accessories for animals

    How to attach accessories

    ECG

  • Attach a patient’s electrode to the sites shown below.
  • IEC AAMI Attaching site
    Lead Electrode
    Color
    Lead Electrode
    Color
    R Red RA White Just below the clavicle (scapula) near the right shoulder
    L Yellow LA Black Just below the clavicle (scapula) near the left shoulder
    F Green LL Red Lower area of the left side of the abdomen
    N Black RL Green Lower area of the right side of the abdomen
    C White V Brown Select the candidate lead for measurement among the chest leads
  • Notices

  • - The default setting of ECG Lead is Lead II.
  • - When using an ECG 5-lead cable, you need to set the Menu for a 5 lead ECG cable.
  • - Be certain the correct setting within the ECG configure-cable menu is chosen to match the cable you are using (3 or 5 lead).
    If the wrong cable is chosen in the menu settings, the monitor will be unable to display any ECG information.
  • NIBP

  • An anesthetized patient’s blood pressure should be regularly monitored.
    The Patient Monitor uses the oscillometric method to obtain systolic, diastolic, and mean non-invasive blood
    pressure measurements. Most text books advise maintaining systolic blood pressure (SAP) at or above 90 mmHg and
    mean arterial blood pressure (MAP) above 70 mmHg. The trend of the MAP is usually the focus of concern.
    It is recommended to take several readings over time. Discard the first and average the next 3 to 7 consecutive readings
    for the most accurate report. It is important to keep the patient relaxed and still.
    The owner may need to assist in calming the patient for best results.
    Multiple measurements may be necessary to achieve accurate results if significant movement of the patient occurs while
    the measurements are being taken. Eliminate any outlier readings that will distort the average readings.
    The chosen cuff size is crucial in obtaining accurate blood pressure measurements.
    For dogs, the cuff width should be approximately 40% of the appendage circumference.
    For cats the cuff width should be approximately 30% of the appendage circumference.
    Cuffs that are too wide will lead to false low readings and cuffs that are too narrow will lead to false high readings.
    Cuff location is also crucial in obtaining accurate blood pressure measurements.
    The limb being cuffed should be at heart level in lateral or sternal recumbency (see illustration below).
    For smaller animals, the cuff should be distal to the elbow on the forelimb or around the midmetatarsus distal to the
    stifle on the hind limb. The base of the tail can also be a valid position to measure blood pressure.
    In larger animals, possible locations include the metacarpus, metatarsus, and distal tibia just above
  • Notices

  • - A patient’s movement during measurement may cause inaccurate results.
  • - Do not use with any other respiration equipment. Choose the cuff type which is appropriate to the patient
  • - In the event a good blood pressure reading is not recorded on the initial cycle, the monitor will attempt a second reading. If this fails, the unit will revert to standby mode. Check the BP line and cuff condition as well as size and placement.
  • - Wrapping the cuff too tightly or too loosely on the measuring site may cause errors in the value.

    SpO2

  • For stable measurement, minimize patient movement.
  • Notices

  • If results are not available at all or are inaccurate, please check the following:
  • - Reposition the sensor or change to another part of the body to correct poor or inaccurate readings.
  • - Check if the sensor is properly placed.
  • - The sensor site should be clean and free of oils and lotions.

    MULTI-LANGUAGE

  • ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH, PORTUGUESE, BRAZIL, TURKISH, RUSSIAN, CZECH, PUMANIAN, POLISH

    DURABLE, AND LIGHT LI-ION BATTERY OPERATION

  • STD. (1PACK) : 2hrs OR MORE
    OPT. (2PACKS) : 4hrs OR MORE

    ECG OUTPUT (OPT)

  • YOU CAN DOWNLOAD AND CAPTURE ECG ANALOG SIGNAL FOR MORE ANALYSIS
  • LoFlo Side stream CO2 Sensor CAPNOSTAT 5 Mainstream CO2 Sensor Phaseln’s Multi-gas
    21st Century CO2 Technology for side stream CO2 monitoring in both intubated and nonintubated patients. 21st Century CO2 Technology for main stream CO2 monitoring in critically ill, intubated patients. Mainstream(IRMA AX+)
    Sidestream(ISA AX+, OR+)